2003 Noise Figure Results
2003 Noise Figure (NF) Results
Tested in Tulsa, OK - July 26, 2003
144 MHz | Call | Design | Device | NF (dB) | Gain (dB) |
---|---|---|---|---|---|
W5UWB | Com'l. LNA | ATF33143 | 0.1 | 23 | |
WD5AGO | HB Cavity - High IP | FSC53 | 0.22 | 23 | |
K5GW | AGO Helix | ATF33143 | 0.28 | 22 | |
K0YW | HB | MGF1302 | 0.3 | 24 | |
W7QX | HB Helix | ATF54143 | 0.54 | 25 | |
WW2R | NTST SSB | 0.85 | 20 | ||
K0YW | HB- 1969 | U310 | 1.3 | 12 | |
222 MHz | Call | Design | Device | NF (dB) | Gain (dB) |
WD5AGO | HB High IP Helix | ATF33143 | 0.22 | 21 | |
K5LLL | Com'l ARR | 1 | 19 | ||
432 MHz | Call | Design | Device | NF (dB) | Gain (dB) |
K0YW | Cavity | 0.22 | 19 | ||
WD5AGO | HB Series L, High IP | ATF33143 | 0.31 | 20 | |
902 MHz | Call | Design | Device | NF (dB) | Gain (dB) |
K5LLL | SERIES-L | ATF101+MAR-1 | 0.7 | 33 | |
K5LLL | Com'l | 4.2 | 20 | ||
1296 MHz | Call | Design | Device | NF (dB) | Gain (dB) |
VE9DW | HB CAVITY | NE329 | 0.23 | 18 | |
WD5AGO | HB 2stage-AGO | NE325-ATF10135 | 0.28 | 31 | |
K0YW | CNK | AT30677 | 0.28 | 19 | |
K5GW | AGO | NE3210 | 0.37 | 30 | |
W0LMD | WD5AGO | NE3210 - ATF34143 | 0.38 | 32 | |
K0YW | WJF | AT36077 | 0.5 | 16 | |
N6TX | Mod. DEMI 23-21cm | 2 stage | 0.6 | 27 | |
WW2R | Com'l DEMI | NE3210 | 0.7 | 18 | |
K0YW | DEMI | 0.7 | 15 | ||
K5LLL | HB DEMI | ATF101 | 0.81 | 15 | |
W7QX | CNK | 0.94 | 20 | ||
W0LMD | Com'l ICOM | 1.7 | 17 | ||
2304 MHz | Call | Design | Device | NF (dB) | Gain (dB) |
K5VH | DEMI | 0.4 | 19 | ||
WD5AGO | HB 2stage | ATF36077-34143 | 0.46 | 25 | |
3456 MHz | No Entry | ||||
5760 MHz | Call | Design | Device | NF (dB) | Gain (dB) |
WA8RJF | DEMI-W5LUA | ATF36077 | 0.85 | 13 | |
WD5AGO | HB LUA | NE310 | 1.02 | 12 | |
10 GHz | No Entry | ||||
24 GHz | Call | Design | Device | NF (dB) | Gain (dB) |
W5LUA | HB LNA | 2 X NE32584C | 1.9 | 15 | |
W5LUA | Avantek | SMW 94-1044 | 2.5 | 28 | |
47 GHz | Call | Design | Device | NF (dB) | Gain (dB) |
W5LUA | HB Rcv converter w/LNA | 4.66 | 35 |
Tested by W5LUA, WA8RJF, and WD5AGO.
Equipment by Agilent Technologies, W5LUA and W9GA.
Compiled by WA8RJF.
HP346A Noise Source, Measurement Accuracy of system according to HP is +/- 0.2 dB!
HP 8970B and Agilent N8975A Noise Figure Analyzer
For 47 GHz: HP342A Noise Figure Meter with 33 - 50 GHz Gas tube Noise head & 10 dB attenuator